Rooftop Fall Protection Anchor Annual Inspection

Rooftop Fall Protection Anchor Annual Inspection

Annual inspection record for permanent rooftop fall protection anchors used by HVAC service technicians, including visual condition checks, attachment integrity, and load test or recertification status where applicable per OSHA and ANSI Z359 guidance.

Inspection Details

  • Inspection date and time recorded
  • Inspector identified as qualified person
    Record the inspector name, title, and qualification basis.
  • Anchor system ID / asset tag recorded
  • Roof location documented
    Include building, roof area, gridline, elevation, or other location detail sufficient to uniquely identify the anchor.

Anchor Identification and Installation

  • Anchor type matches approved design
  • Anchor and mounting hardware are securely installed
    Verify no looseness, movement, missing components, or visible separation at the mounting interface.
  • Fasteners present and intact
    Check for missing, damaged, stripped, or substituted fasteners; verify locking devices or torque retention features where applicable.
  • Roof substrate and structural attachment show no visible distress
    Inspect for cracking, deformation, water intrusion, rot, corrosion, or other signs that the substrate or structural member may have been compromised.

Condition and Serviceability

  • Anchor shows no deformation, cracks, or weld damage
    Inspect all visible anchor components for bending, elongation, cracking, broken welds, or other structural damage.
  • Corrosion or deterioration within acceptable limits
    Check for rust, pitting, coating failure, UV degradation, or other deterioration that could affect performance.
  • Anchor label or identification markings legible
    Verify manufacturer identification, capacity rating, installation date, and inspection label are present and readable.
  • Anchor is free of obstructions and accessible for use
    Confirm the anchor can be reached and used without removing permanent barriers, debris, or stored materials.
  • No evidence of unauthorized modification or repair
    Look for field welding, drilling, cut components, non-approved replacement parts, or other non-conforming alterations.

Load Test, Recertification, and Compliance

  • Annual inspection completed by qualified person
  • Load test or recertification performed when required
    Document whether a load test, recertification, or visual-only inspection was performed based on the anchor manufacturer's instructions, site program, and any reroofing or renovation work.
  • Inspection result meets OSHA / ANSI Z359 requirements
    Confirm the anchor remains suitable for continued service based on the inspection findings and applicable manufacturer and site requirements.
  • Date of last reroofing or roof renovation recorded
    If reroofing or renovation occurred, record the date to support recertification tracking.

Deficiencies and Corrective Actions

  • Deficiencies documented with corrective action
    Record all deficiencies, non-conformances, and required corrective actions, including removal from service if applicable.
  • Anchor removed from service if unsafe
    Use this item when the anchor is unsafe, damaged, or non-compliant and must be tagged out until repaired or replaced.

Inspector Sign-Off

  • Inspector signature
  • Supervisor or AHJ review completed
    Optional review by supervisor, safety manager, or Authority Having Jurisdiction if required by site policy.