Loading...

Run: Rooftop Fall Protection Anchor Annual Inspection

Annual inspection record for permanent rooftop fall protection anchors used by HVAC technicians. Use it to document anchor condition, installation integrity,...

Fill this out, get a PDF emailed to you. No account required. Want to run it with your team and track results? Sign up free →

Inspection Details

Record the inspector name, title, and qualification basis.
Include building, roof area, gridline, elevation, or other location detail sufficient to uniquely identify the anchor.

Anchor Identification and Installation

Verify no looseness, movement, missing components, or visible separation at the mounting interface.
Check for missing, damaged, stripped, or substituted fasteners; verify locking devices or torque retention features where applicable.
Inspect for cracking, deformation, water intrusion, rot, corrosion, or other signs that the substrate or structural member may have been compromised.

Condition and Serviceability

Inspect all visible anchor components for bending, elongation, cracking, broken welds, or other structural damage.
Check for rust, pitting, coating failure, UV degradation, or other deterioration that could affect performance.
Verify manufacturer identification, capacity rating, installation date, and inspection label are present and readable.
Confirm the anchor can be reached and used without removing permanent barriers, debris, or stored materials.
Look for field welding, drilling, cut components, non-approved replacement parts, or other non-conforming alterations.

Load Test, Recertification, and Compliance

Document whether a load test, recertification, or visual-only inspection was performed based on the anchor manufacturer's instructions, site program, and any reroofing or renovation work.
Confirm the anchor remains suitable for continued service based on the inspection findings and applicable manufacturer and site requirements.
If reroofing or renovation occurred, record the date to support recertification tracking.

Deficiencies and Corrective Actions

Record all deficiencies, non-conformances, and required corrective actions, including removal from service if applicable.
Use this item when the anchor is unsafe, damaged, or non-compliant and must be tagged out until repaired or replaced.

Inspector Sign-Off

Optional review by supervisor, safety manager, or Authority Having Jurisdiction if required by site policy.

Get your results

Enter your email — we'll send you a PDF of your filled-out template, plus the occasional MangoScoop newsletter (templates, workflow tips, product updates). Unsubscribe anytime — link is in every email.