Laminate Bond Strength Test Record
Laminate Bond Strength Test Record
Records peel bond strength results for laminated film samples pulled from production and verifies the measured bond strength meets specification to reduce delamination risk during converting and end use.
Inspection Identification
-
Production lot or work order identified
Record the lot number, work order, or batch identifier for the laminated film sample.
-
Sample date and time recorded
Capture when the sample was pulled from production.
-
Sample source identified
Select where the sample originated.
-
Sample identification label present and legible
Verify the sample label matches the production record and is readable.
-
Specification or acceptance criteria referenced
Enter the minimum acceptable peel strength and any special acceptance criteria.
-
Test method referenced
Document the method used for the peel bond strength test.
Sample Condition and Preparation
-
Sample condition acceptable before test
Confirm the sample is intact, not visibly damaged, and suitable for testing.
-
Conditioning environment recorded
Record conditioning temperature, humidity, and duration if required by the method.
-
Specimen dimensions recorded
Enter specimen width or other required dimensions used for the peel test.
-
Number of test replicates prepared
Record the number of peel test replicates prepared for the sample.
-
Specimen edges and bond area prepared per method
Verify the specimen was cut, separated, and prepared according to the approved method.
Test Setup and Apparatus
-
Test machine or force gauge identified
Record the instrument ID used for the peel test.
-
Instrument calibration current
Confirm the test instrument calibration is current and traceable.
-
Crosshead speed or pull rate recorded
Enter the pull rate used for the peel test.
-
Grip or fixture setup matches method
Verify the grips, fixtures, and alignment match the approved test method.
-
Test environment recorded
Record ambient temperature and humidity during testing if required.
Peel Strength Results
-
Replicate 1 peel strength
Enter the measured peel strength for the first replicate.
-
Replicate 2 peel strength
Enter the measured peel strength for the second replicate.
-
Replicate 3 peel strength
Enter the measured peel strength for the third replicate.
-
Average peel strength
Record the calculated average peel strength across all replicates.
-
Failure mode observed
Select the dominant failure mode observed during peel testing.
Compliance Review and Disposition
-
Results meet specification
Confirm the measured peel strength meets the minimum acceptance criteria.
-
Delamination risk acceptable for converting and end use
Assess whether the laminate is suitable for downstream converting and intended end use.
-
Non-conformance documented if out of spec
If any result is below spec, confirm a non-conformance or deviation record was opened.
-
Inspector signature
Inspector or lab technician sign-off.