Checkweigher Verification and Calibration Log
Checkweigher Verification and Calibration Log
Inspection log for documenting test weight checks, reject confirmation, and calibration verification on an in-line checkweigher to confirm weight accuracy and reject function.
Inspection Details
- Inspection date and time recorded
- Production line and checkweigher ID identified
- Product or SKU being run
- Inspector or operator name
- Inspection type
Equipment Condition and Readiness
- Checkweigher is clean, powered on, and ready for use
- Conveyor, guides, and product flow path are clear of obstructions
- Display, controls, and alarms are functioning normally
- Last calibration or verification label is current
Test Weight Verification
- Test weight set used for verification
- Nominal test weight value
- Measured result at low end of operating range
- Measured result at target or nominal weight
- Measured result at high end of operating range
- All test weight results are within the approved tolerance
Reject Function Confirmation
- Reject device actuates when an out-of-spec test pack is introduced
- Rejected unit is diverted to the correct reject bin or lane
- Reject confirmation is visible and documented by the system or operator
- Reject timing and response are acceptable
Calibration Status and Outcome
- Calibration adjustment was required
- Calibration completed successfully
- Equipment returned to service after verification
Deficiencies and Corrective Actions
- Deficiencies or non-conformances noted
- Corrective action taken
- Supervisor or QA review completed