Inspection Scope and Boiler Identification

  • Boiler identification recorded
    Record boiler tag number, manufacturer, model, serial number, capacity, and location.
  • Inspection date and inspector credentials recorded
    Document the inspection date, inspector name, and license or authorization details as required by the AHJ.
  • Boiler type and service verified
    Confirm the boiler type and service category for the record.
  • Inspection scope includes external and internal examination
    Verify that both external and internal inspection activities are included in this annual review.
  • Applicable jurisdiction and code basis documented
    Record the state jurisdiction, ASME Section VI reference, and any applicable local boiler rules used for the inspection.

Certificate Posting and Compliance Records

  • Current boiler inspection certificate posted or available
    Confirm the current annual inspection certificate is posted at the boiler or maintained where required by the AHJ.
  • Certificate matches boiler identification
    Verify the certificate or record matches the boiler location, serial number, and jurisdiction.
  • Certificate issue and expiration dates recorded
    Record the issue date, expiration date, and inspection cycle applicable to this boiler.
  • Prior deficiencies and corrective actions reviewed
    Confirm previous inspection findings were reviewed and closed or tracked to completion.
  • Required records available for AHJ review
    Verify maintenance logs, repair records, and prior inspection reports are available for review.

External Condition and Operating Controls

  • No active leaks, visible corrosion, or abnormal staining
    Inspect the boiler exterior, piping, fittings, and nearby surfaces for leaks, corrosion, or evidence of water discharge.
  • Pressure/temperature gauges readable and within normal operating range
    Verify gauges are legible, properly mounted, and indicate normal operating conditions.
  • Low-water cutoff, pressure controls, and operating controls present and intact
    Confirm required operating and safety controls are installed, accessible, and show no visible damage.
  • Safety relief valve discharge piping and termination acceptable
    Verify discharge piping is properly routed, unobstructed, and terminates in a safe location.
  • Burner, ignition, and fuel train area free of obvious defects
    Check for damaged components, loose connections, soot accumulation, or signs of improper combustion.
  • Housekeeping and access around boiler adequate
    Verify the boiler room is accessible, free of combustible storage in unsafe proximity, and allows safe inspection and maintenance access.

Internal Condition and Water-Side Examination

  • Boiler safely shut down, isolated, and opened for internal inspection
    Confirm lockout-tagout, isolation, depressurization, and safe access were completed before internal examination.
  • Internal surfaces free of heavy scale, sludge, or pitting
    Inspect waterside surfaces for scale buildup, sludge, pitting, or other deterioration affecting safe operation.
  • No evidence of cracking, bulging, distortion, or overheating
    Check pressure parts, tubes, drums, and accessible internal surfaces for structural distress or heat damage.
  • Water-side corrosion condition documented
    Rate the overall internal corrosion condition observed during inspection.
  • Manway, handhole, and gasket surfaces acceptable
    Verify openings, covers, and gasket surfaces are serviceable and free of damage that would prevent proper reassembly.
  • Internal inspection findings documented
    Record all internal observations, including deposits, repairs needed, and any areas requiring follow-up.

Safety Devices, Testing, and Corrective Actions

  • Safety relief valve condition acceptable
    Confirm the relief valve shows no leakage, corrosion, tampering, or signs of improper installation.
  • Required safety device tests performed or witnessed
    Record whether applicable safety device tests were performed, witnessed, or verified per site procedure and jurisdictional requirements.
  • Deficiencies and non-conformances documented
    List all deficiencies, non-conformances, and critical items requiring repair, retest, or AHJ notification.
  • Corrective action owner and due date assigned
    Identify the responsible person or contractor and the target completion date for each corrective action.
Ask AI Template Studio

Let's customize Boiler Annual External and Internal Inspection.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?