Loading...

Run: Weatherstripping Installation Verification

Verify that the installed weatherstrip matches the approved door specification, seats correctly, and seals the full perimeter without interfering with door o...

Fill this out, get a PDF emailed to you. No account required. Want to run it with your team and track results? Sign up free →

Inspection Identification

Record the door number, job/order number, location, and inspection date.
Document the approved weatherstrip type, profile, finish, and reference document used for verification.
Enter the name or ID of the inspector completing the verification.
Confirm the door is fully assembled and ready for final QC verification.

Weatherstrip Type and Installation

Verify the installed weatherstrip type, profile, and material match the approved specification and have not been substituted or modified.
Check that the weatherstrip is properly inserted, seated, and retained without lifting, twisting, or partial engagement.
Inspect the installed weatherstrip for physical damage, compression set, splits, or other defects that could affect sealing performance.

Continuity and Seal Coverage

Verify continuous coverage at all required contact edges with no missing sections, breaks, or open joints.
Check that corners and splice points are cleanly joined and do not create gaps, overlaps, or discontinuities in the seal line.
Rate the uniformity of weatherstrip contact against the mating surface across the full perimeter.

Door Fit and Functional Check

Confirm the door closes fully and latches properly without excessive force, drag, or interference from the weatherstrip.
Measure any visible perimeter gap where applicable and record the result.
Verify the seal does not obstruct hinges, latches, closers, astragals, thresholds, or other installed hardware.

Compliance, Deficiencies, and Sign-Off

If the door is fire-rated, confirm the weatherstripping installation does not modify the listed assembly and remains consistent with the approved fire door components and AHJ requirements. Reference NFPA 80 where applicable.
List any non-conformances, including missing sections, misalignment, damaged material, or rework required.
Inspector signs to confirm the verification was completed accurately.

Get your results

Enter your email — we'll send you a PDF of your filled-out template, plus the occasional MangoScoop newsletter (templates, workflow tips, product updates). Unsubscribe anytime — link is in every email.

Generated with MangoApps Templates — browse 250+ free