Run: Transformer Oil Dielectric Breakdown Test (ASTM D1816/D877)

Record transformer oil dielectric breakdown test results, sample traceability, and pass/fail disposition for ASTM D1816 or ASTM D877. Use it to document diel...

Fill this out, get a PDF emailed to you. No account required. Want to run it with your team and track results? Sign up free →

Inspection Identification and Sample Traceability

Enter the equipment ID, transformer nameplate number, or asset tag associated with the sampled oil.
Document the unique sample identifier and when the oil specimen was collected.
Record the source compartment or sampling point, such as main tank, conservator, or bushing compartment.
Select the method used for the dielectric breakdown test.
Confirm the sample remained identified and controlled from collection through testing.
Enter the internal procedure, laboratory SOP, or work instruction used for the test.

Specimen Condition and Test Setup

Confirm the specimen is suitable for testing and does not show obvious contamination, excessive free water, or foreign matter that would invalidate the run.
Confirm the dielectric test vessel or cell is clean, dry, and free of residue before filling.
Verify electrodes are clean, properly spaced, and free of pitting, corrosion, or contamination.
Confirm the dielectric test set or BDV tester is within calibration and suitable for use.
Record the specimen temperature at the time of test.
Document the applicable acceptance limit, utility specification, OEM requirement, or internal threshold used to judge the result.

Dielectric Breakdown Test Results

Enter the first measured breakdown voltage.
Enter the second measured breakdown voltage.
Enter the third measured breakdown voltage.
Enter the fourth measured breakdown voltage.
Enter the fifth measured breakdown voltage.
Record the calculated average BDV for the specimen.
Indicate whether arcing irregularities, unstable readings, or other anomalies occurred during the test.

Compliance Review and Disposition

Confirm the average BDV meets the applicable specification or internal acceptance limit.
Select the final disposition for the oil sample based on the test result.
Describe any required retest, filtration, dehydration, oil replacement, or maintenance follow-up.

Sign-Off and Traceability

Inspector or analyst signs to confirm the recorded results are accurate.
Record the date and time the inspection record was reviewed or approved.
Attach a photo, scan, or lab report image if available.

Get your results

Enter your email — we'll send you a PDF of your filled-out template, plus the occasional MangoScoop newsletter (templates, workflow tips, product updates). Unsubscribe anytime — link is in every email.

Generated with MangoApps Templates — browse 250+ free
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?