Run: ASTM F1417 Sanitary Sewer Low-Pressure Air and Mandrel Deflection Test

Use this ASTM F1417 sanitary sewer test template to record low-pressure air testing and mandrel deflection verification for new gravity sewer acceptance. It ...

Fill this out, get a PDF emailed to you. No account required. Want to run it with your team and track results? Sign up free →

Inspection Details and Project Identification

Record the project name, site address, and sewer reach or station limits being tested.
Document when the air test or mandrel test was performed.
Identify the manhole-to-manhole reach, lateral, stationing, or segment number.
Record pipe material, nominal diameter, and tested length for the segment.
Select the governing acceptance specification for this test record.

Pre-Test Installation and Safety Conditions

Confirm the test section is isolated, plugged, and sealed at all openings before pressurization.
Verify the work zone is controlled and personnel are clear before introducing air pressure.
Confirm hoses, regulators, gauges, and fittings are in good condition and suitable for the test.
Verify pressure control and relief devices are in place to prevent over-pressurization.
Confirm the line is free of debris, standing water, and obstructions that could affect the test.

Low-Pressure Air Test Setup and Conditions

Record the specified test pressure used for the air test.
Confirm the line was allowed to stabilize before the timed test period began.
Verify the pressure gauge used for the test is within its calibration or verification interval.
Record weather, temperature, groundwater influence, or other conditions that may affect test results.
Enter the timed duration used for the acceptance test.

Air Test Results and Acceptance

Record the pressure at the start of the timed test period.
Record the pressure at the end of the test period.
Indicate whether the pressure loss met the acceptance criteria for the tested segment.
Record whether any leaks, joint failures, or other defects were observed during the test.
Select the final result for the low-pressure air test.

Mandrel Deflection Test

Confirm the mandrel deflection test was performed after the required curing or waiting period per project specification.
Record the mandrel diameter, number of arms, and any project-specific configuration details.
Verify the mandrel passes freely through the tested section, indicating acceptable deflection.

Deficiencies, Corrective Actions, and Sign-Off

List any deficiencies, non-conformances, or failed test conditions.
Describe required repairs, retesting, or follow-up actions.
Inspector sign-off confirming the record is complete and accurate.
Optional acceptance acknowledgment by the contractor or owner representative.

Get your results

Enter your email — we'll send you a PDF of your filled-out template, plus the occasional MangoScoop newsletter (templates, workflow tips, product updates). Unsubscribe anytime — link is in every email.

Generated with MangoApps Templates — browse 250+ free