Weatherstripping Installation Verification
Weatherstripping Installation Verification
Inspection template for door assembly QC to verify weatherstrip type, seating, continuity, and seal integrity on assembled doors.
Inspection Identification
-
Door and job identification recorded
Record the door number, job/order number, location, and inspection date.
-
Weatherstrip specification or BOM reference available
Document the approved weatherstrip type, profile, finish, and reference document used for verification.
-
Inspector identified
Enter the name or ID of the inspector completing the verification.
-
Inspection stage confirmed as assembled door QC
Confirm the door is fully assembled and ready for final QC verification.
Weatherstrip Type and Installation
-
Installed weatherstrip matches approved specification
Verify the installed weatherstrip type, profile, and material match the approved specification and have not been substituted or modified.
-
Weatherstrip is fully seated in the intended retainer or kerf
Check that the weatherstrip is properly inserted, seated, and retained without lifting, twisting, or partial engagement.
-
No visible cuts, tears, deformation, or damage
Inspect the installed weatherstrip for physical damage, compression set, splits, or other defects that could affect sealing performance.
Continuity and Seal Coverage
-
Weatherstrip continuity is complete around required perimeter
Verify continuous coverage at all required contact edges with no missing sections, breaks, or open joints.
-
Corners, joints, and end conditions are properly joined
Check that corners and splice points are cleanly joined and do not create gaps, overlaps, or discontinuities in the seal line.
-
Compression and contact appear uniform along the seal line
Rate the uniformity of weatherstrip contact against the mating surface across the full perimeter.
Door Fit and Functional Check
-
Door closes and latches without binding on weatherstrip
Confirm the door closes fully and latches properly without excessive force, drag, or interference from the weatherstrip.
-
Visible gap or light leakage at perimeter is within acceptable limit
Measure any visible perimeter gap where applicable and record the result.
-
Weatherstrip does not interfere with hinges, hardware, or thresholds
Verify the seal does not obstruct hinges, latches, closers, astragals, thresholds, or other installed hardware.
Compliance, Deficiencies, and Sign-Off
-
Fire-rated assembly requirements considered where applicable
If the door is fire-rated, confirm the weatherstripping installation does not modify the listed assembly and remains consistent with the approved fire door components and AHJ requirements. Reference NFPA 80 where applicable.
-
Deficiencies documented with corrective action
List any non-conformances, including missing sections, misalignment, damaged material, or rework required.
-
Inspector signature
Inspector signs to confirm the verification was completed accurately.
Ask AI