Inspection template for door assembly QC to verify weatherstrip type, seating, continuity, and seal integrity on assembled doors.

Inspection Identification

  • Door and job identification recorded
    Record the door number, job/order number, location, and inspection date.
  • Weatherstrip specification or BOM reference available
    Document the approved weatherstrip type, profile, finish, and reference document used for verification.
  • Inspector identified
    Enter the name or ID of the inspector completing the verification.
  • Inspection stage confirmed as assembled door QC
    Confirm the door is fully assembled and ready for final QC verification.

Weatherstrip Type and Installation

  • Installed weatherstrip matches approved specification
    Verify the installed weatherstrip type, profile, and material match the approved specification and have not been substituted or modified.
  • Weatherstrip is fully seated in the intended retainer or kerf
    Check that the weatherstrip is properly inserted, seated, and retained without lifting, twisting, or partial engagement.
  • No visible cuts, tears, deformation, or damage
    Inspect the installed weatherstrip for physical damage, compression set, splits, or other defects that could affect sealing performance.

Continuity and Seal Coverage

  • Weatherstrip continuity is complete around required perimeter
    Verify continuous coverage at all required contact edges with no missing sections, breaks, or open joints.
  • Corners, joints, and end conditions are properly joined
    Check that corners and splice points are cleanly joined and do not create gaps, overlaps, or discontinuities in the seal line.
  • Compression and contact appear uniform along the seal line
    Rate the uniformity of weatherstrip contact against the mating surface across the full perimeter.

Door Fit and Functional Check

  • Door closes and latches without binding on weatherstrip
    Confirm the door closes fully and latches properly without excessive force, drag, or interference from the weatherstrip.
  • Visible gap or light leakage at perimeter is within acceptable limit
    Measure any visible perimeter gap where applicable and record the result.
  • Weatherstrip does not interfere with hinges, hardware, or thresholds
    Verify the seal does not obstruct hinges, latches, closers, astragals, thresholds, or other installed hardware.

Compliance, Deficiencies, and Sign-Off

  • Fire-rated assembly requirements considered where applicable
    If the door is fire-rated, confirm the weatherstripping installation does not modify the listed assembly and remains consistent with the approved fire door components and AHJ requirements. Reference NFPA 80 where applicable.
  • Deficiencies documented with corrective action
    List any non-conformances, including missing sections, misalignment, damaged material, or rework required.
  • Inspector signature
    Inspector signs to confirm the verification was completed accurately.
Ask AI Template Studio

Let's customize Weatherstripping Installation Verification.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?