Vacuum Interrupter Open-Gap Withstand Test Inspection

Vacuum Interrupter Open-Gap Withstand Test Inspection

Inspection template for recording high-voltage withstand results across open vacuum interrupter contacts to verify vacuum integrity and identify loss of vacuum through withstand failure.

Inspection Identification

  • Equipment identification recorded
    Enter the switchgear, breaker, or vacuum interrupter asset ID, serial number, or unique equipment tag.
  • Test location recorded
    Enter the facility, room, lineup, cubicle, or field location where the test was performed.
  • Test date and time recorded
    Record when the withstand test was performed.
  • Reason for test documented
    Select the operational reason for performing the test.

Safety and Test Readiness

  • Lockout-tagout applied and verified
    Confirm the equipment is de-energized and isolated under an approved lockout-tagout procedure.
  • Qualified personnel and test boundaries established
    Confirm only qualified personnel are present and the test area is controlled.
  • Required PPE available and worn
    Select all PPE used for the test activity.
  • Test instrument and leads inspected
    Confirm the hipot/test set, leads, grounding, and connectors are in safe condition with no visible damage.

Test Setup and Equipment

  • Test instrument identification recorded
    Enter the make, model, and serial number of the high-voltage test set or hipot unit.
  • Calibration status current
    Confirm the test instrument calibration is current and traceable.
  • Open-gap test configuration verified
    Confirm the vacuum interrupter contacts are open and the test is configured across the open gap.
  • Grounding and discharge arrangement verified
    Confirm proper grounding and discharge procedures are in place before and after the test.

Withstand Test Results

  • Applied test voltage recorded
    Enter the applied high-voltage withstand level used for the test.
  • Test duration recorded
    Enter the duration that voltage was held across the open contacts.
  • Withstand result
    Select whether the interrupter maintained dielectric withstand across the open gap.
  • Evidence of vacuum loss or dielectric breakdown observed
    Select any abnormal observations during the withstand test.

Deficiencies and Corrective Actions

  • Deficiency or non-conformance documented
    Describe any deficiency, abnormal reading, or failed test condition.
  • Corrective action initiated
    Record the immediate corrective action, repair plan, or escalation taken after a failed test.
  • Equipment tagged out of service if failed
    Confirm failed equipment was removed from service or otherwise controlled pending disposition.

Sign-Off

  • Inspector signature
    Signature of the person performing the inspection/test.
  • Reviewer or supervisor acknowledgment
    Optional review signature for QA, maintenance, or supervisory approval.