Utility Vault and Manhole Atmospheric Pre-Entry Test

Utility Vault and Manhole Atmospheric Pre-Entry Test

Pre-entry atmospheric test record for utility vaults and manholes documenting oxygen, LEL, carbon monoxide, and hydrogen sulfide readings at multiple depths before personnel entry.

Inspection Details

  • Inspection date and time recorded
  • Location identified
    Record the vault/manhole ID, address, utility type, and exact access point.
  • Inspector and tester identified
    Record the name and role of the person performing the atmospheric test.

Test Equipment and Calibration

  • Gas monitor bump-tested and within calibration
    Confirm the instrument was bump-tested per site procedure and is within the current calibration interval before use.
  • Instrument serial number recorded
    Record the serial number or asset ID of the gas monitor used for the test.
  • Sampling method and probe length documented
    Document whether a pump, probe, or diffusion method was used and the approximate probe length or sampling setup.

Atmospheric Readings

  • Top reading recorded
    Enter the top-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
  • Middle reading recorded
    Enter the middle-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
  • Bottom reading recorded
    Enter the bottom-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
  • Oxygen within acceptable range
    Confirm oxygen concentration is within the site-accepted safe range for entry.
  • LEL below entry limit
    Confirm combustible gas concentration is below the site-accepted entry limit.
  • Carbon monoxide below entry limit
    Confirm carbon monoxide is below the site-accepted exposure limit for entry.
  • Hydrogen sulfide below entry limit
    Confirm hydrogen sulfide is below the site-accepted exposure limit for entry.

Ventilation and Re-Test

  • Ventilation in place when required
    Confirm forced air ventilation or other control measures are operating when required by the entry procedure.
  • Re-test performed after ventilation or condition change
    Confirm the atmosphere was re-tested after ventilation, weather change, equipment change, or any condition that could affect readings.

Entry Authorization and Sign-Off

  • Entry authorized based on test results
    Confirm the space was authorized for entry only after acceptable atmospheric readings were verified.
  • Deficiencies and corrective actions documented
    Document any out-of-range readings, ventilation actions, retesting, or entry delays.
  • Inspector signature