Utility Vault and Manhole Atmospheric Pre-Entry Test
Utility Vault and Manhole Atmospheric Pre-Entry Test
Pre-entry atmospheric test record for utility vaults and manholes documenting oxygen, LEL, carbon monoxide, and hydrogen sulfide readings at multiple depths before personnel entry.
Inspection Details
- Inspection date and time recorded
-
Location identified
Record the vault/manhole ID, address, utility type, and exact access point.
-
Inspector and tester identified
Record the name and role of the person performing the atmospheric test.
Test Equipment and Calibration
-
Gas monitor bump-tested and within calibration
Confirm the instrument was bump-tested per site procedure and is within the current calibration interval before use.
-
Instrument serial number recorded
Record the serial number or asset ID of the gas monitor used for the test.
-
Sampling method and probe length documented
Document whether a pump, probe, or diffusion method was used and the approximate probe length or sampling setup.
Atmospheric Readings
-
Top reading recorded
Enter the top-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
-
Middle reading recorded
Enter the middle-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
-
Bottom reading recorded
Enter the bottom-of-space readings for oxygen, LEL, carbon monoxide, and hydrogen sulfide.
-
Oxygen within acceptable range
Confirm oxygen concentration is within the site-accepted safe range for entry.
-
LEL below entry limit
Confirm combustible gas concentration is below the site-accepted entry limit.
-
Carbon monoxide below entry limit
Confirm carbon monoxide is below the site-accepted exposure limit for entry.
-
Hydrogen sulfide below entry limit
Confirm hydrogen sulfide is below the site-accepted exposure limit for entry.
Ventilation and Re-Test
-
Ventilation in place when required
Confirm forced air ventilation or other control measures are operating when required by the entry procedure.
-
Re-test performed after ventilation or condition change
Confirm the atmosphere was re-tested after ventilation, weather change, equipment change, or any condition that could affect readings.
Entry Authorization and Sign-Off
-
Entry authorized based on test results
Confirm the space was authorized for entry only after acceptable atmospheric readings were verified.
-
Deficiencies and corrective actions documented
Document any out-of-range readings, ventilation actions, retesting, or entry delays.
- Inspector signature