Tempered Glass Fragmentation Test Log

Tempered Glass Fragmentation Test Log

Inspection log for recording tempered glass fragmentation test results, including fragment counts in a 50 x 50 mm area after breakage, to document conformance with ASTM C1048 and ANSI Z97.1 minimum particle requirements.

Inspection Header and Sample Identification

  • Test date and time recorded
  • Inspector name and role recorded
  • Sample ID, lot number, and product description recorded
  • Glass type confirmed as tempered sample
    Confirm the specimen is identified as tempered glass before fracture testing.
  • Reference standard documented

Test Method and Break Procedure

  • Break method documented and controlled
    Record the method used to fracture the sample and any controlled setup details.
  • Breakage performed under safe, controlled conditions
    Verify the sample was broken in a controlled manner with appropriate PPE and handling.
  • Fragment count recorded within 3 to 5 minutes after fracture
    Enter the elapsed time used for the count.
  • Photo evidence of fracture pattern captured
    Upload a clear image of the fractured specimen and fragment field.

Fragment Count Measurement

  • 50 x 50 mm area identified on sample
    Confirm the inspection area used for counting fragments is the specified 50 x 50 mm region.
  • Fragment count within 50 x 50 mm area
  • Fragments are small, granular, and uniformly distributed
    Verify the break pattern is consistent with tempered glass fragmentation.
  • Edge condition and any large shards documented
    Record any abnormal shard size, edge behavior, or unusual fracture characteristics.
  • Minimum particle requirement met
    Pass when the fragment count in the 50 x 50 mm area meets or exceeds the minimum requirement.

Compliance, Non-Conformance, and Sign-Off

  • Test result disposition
  • Non-conformance documented when applicable
    Describe any deficiency, out-of-spec fragment count, or test deviation.
  • Corrective action or disposition recorded
    Record re-test, hold, reject, or other disposition if the sample fails.
  • Inspector signature
  • Reviewer or QA approval
Ask AI Template Studio

Let's customize Tempered Glass Fragmentation Test Log.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?