Stored Asphalt Shingle Stacking and UV Protection Audit
Stored Asphalt Shingle Stacking and UV Protection Audit
Inspection template for verifying stored asphalt shingle stack height, pallet stacking limits, slip-sheet use, and protection from sun exposure to prevent distortion, sticking, and adhesive squeeze-out in line with ARMA and manufacturer guidance.
Inspection Details
-
Inspection location identified
Record the yard, warehouse, jobsite, or storage area being inspected.
-
Storage area type
Select the primary storage environment for the shingles.
-
Inspection date and time
Document when the storage audit was performed.
Stack Height and Pallet Stacking Compliance
-
Stack height within manufacturer-recommended limit
Measure the stack height or count pallet tiers and verify it does not exceed the manufacturer guidance for the specific shingle product.
-
Pallet stacking limit respected
Verify pallets are not stacked higher than allowed and are stable, level, and not overloaded.
-
Stacks are level and not leaning, bowing, or compressed
Check for visible distortion, leaning, crushed corners, or compression from improper stacking.
-
Bundles are stored on stable pallets or dunnage
Confirm bundles are supported on stable, dry pallets or equivalent dunnage and are not in direct contact with the ground.
Slip-Sheets, Separation, and Package Condition
-
Slip-sheets or separators used where required
Verify slip-sheets, separators, or other manufacturer-approved separation methods are in place when required to prevent sticking.
-
No visible sticking between bundles or layers
Inspect for adhered bundles, fused layers, or tearing when separating stacked materials.
-
No adhesive squeeze-out or bleed-through observed
Check for asphalt adhesive squeeze-out, bleed-through, or softened sealant caused by heat exposure or compression.
-
Packaging wrap and labels intact
Confirm wrap, straps, and product identification labels are intact and readable.
Sun Exposure and Environmental Protection
-
Stacks protected from direct sunlight
Verify stored shingles are covered, shaded, or otherwise protected from direct sun exposure that could cause heat-related damage.
-
Storage area temperature or heat exposure controlled
Confirm the storage environment minimizes excessive heat buildup, such as by ventilation, shade, or indoor storage.
-
Stacks protected from rain, moisture, and standing water
Verify shingles are kept dry and protected from water intrusion, pooling, or ground moisture.
-
No evidence of heat damage or UV-related deterioration
Look for curling, warping, softened sealant, granule loss, or other visible deterioration associated with sun exposure.
Visible Damage and Non-Conformance
-
No torn wrap, crushed corners, or damaged bundles
Inspect the stored product for packaging damage, crushed edges, or bundle deformation.
-
Non-conforming product segregated and marked hold
Verify any damaged or suspect shingles are isolated, identified, and not released for installation.
Corrective Action and Sign-Off
-
Corrective actions documented for deficiencies
List each deficiency, the immediate containment action, and the owner and due date for correction.
-
Inspector signature
Inspector signs to confirm findings and completion of the audit.