Loading...

Rooftop Fall Protection Anchor Annual Inspection

Rooftop Fall Protection Anchor Annual Inspection

Annual inspection record for permanent rooftop fall protection anchors used by HVAC service technicians, including visual condition checks, verification of attachment integrity, and documentation of load test or qualified-person inspection per OSHA and ANSI Z359.

Inspection Identification

  • Inspection date and time recorded
  • Building / site name recorded
  • Roof anchor ID or asset tag recorded
  • Inspector is qualified to perform annual anchor inspection
    Inspection must be completed by a qualified person or competent person as defined by the site program.

Anchor Location and Access

  • Anchor location matches site records and roof plan
  • Access to anchor is unobstructed and safe for inspection
  • Anchor identification label or marking is legible
  • Roof surface around anchor is free of trip, slip, or fall hazards

Anchor Physical Condition

  • Anchor shows no visible cracks, bends, deformation, or missing components
  • Fasteners, welds, and base plate are secure and intact
  • No visible corrosion, rust-through, or material deterioration affecting strength
  • Roof membrane, flashing, and waterproofing around anchor are intact
  • Anchor has not been modified, painted over, or altered since last inspection

Load Test or Qualified Visual Inspection

  • Inspection method used
  • Inspection result meets manufacturer and site requirements
  • If load tested, recorded test load
    Record the applied test load if a load test was performed. Verify against the site program, manufacturer instructions, and applicable OSHA criteria.
  • Load test or inspection documentation attached

Deficiencies and Corrective Actions

  • Any deficiency or non-conformance identified
  • Anchor removed from service pending repair or replacement when required
  • Corrective action assigned with responsible person and due date

Sign-Off

  • Inspector signature
  • Supervisor or owner review completed
Ask AI Template Studio

Let's customize Rooftop Fall Protection Anchor Annual Inspection.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.