Roofing Panel Seam and Profile Inspection
Roofing Panel Seam and Profile Inspection
Inspection template for standing seam roof and wall panels coming off the rollformer, verifying rib profile, coverage width, seam quality, and field-fit readiness before installation.
Inspection Setup and Panel Identification
- Panel type, profile, and gauge match the job traveler or shop order
- Panel length, color/finish, and quantity are identified and traceable
- Inspection tools available and suitable for dimensional verification
- Reference profile or approved sample available at inspection station
Rib Profile and Form Accuracy
- Rib profile matches approved profile geometry
- Rib height and shape are consistent along the full panel length
- Rib spacing is uniform and free from waviness or distortion
- Panel is straight with no visible twist, bow, or oil-canning beyond acceptable limits
Coverage Width and Dimensional Verification
- Overall coverage width measured within approved tolerance
- Male and female seam legs are formed to the correct width and depth
- Panel coverage is consistent from end to end
- Cut length, end condition, and squareness support proper field lap and seam engagement
Seam Quality and Field-Fit Readiness
- Seam closes fully and evenly without gaps, splits, or open hems
- Seam alignment is straight and consistent for field lapping and seaming
- Seam edges are free from burrs, sharp deformation, cracks, or coating damage
- Panel end laps, if present, are formed to allow proper overlap and water-shedding performance
Surface Condition, Handling Damage, and Sign-Off
- Surface finish is free from dents, scratches, scuffs, and roll-forming marks that exceed acceptance criteria
- Panels are stacked, tagged, and protected to prevent transit or handling damage
- Non-conformances documented and dispositioned
- Inspector signature