Residential HVAC Rough-In Walk-Through Inspection

Residential HVAC Rough-In Walk-Through Inspection

Pre-drywall inspection template for verifying residential HVAC rough-in, including duct runs, register and return locations, equipment placement, venting, support, and code/manufacturer compliance before walls are closed.

Inspection Details and Reference Documents

  • Project address, lot/unit, and inspection date recorded
  • Approved mechanical plans and permit set available on site
  • Installation verified against manufacturer instructions and AHJ requirements

Equipment Location and Clearances

  • Air handler, furnace, or indoor unit set in approved location
  • Required service clearances maintained around equipment
    Verify access for filter replacement, coil service, burner service where applicable, and panel removal.
  • Equipment platform, hanger, or support is secure and level
  • Refrigerant line set and condensate routing are protected and routed without damage risk

Ductwork Layout, Sizing, and Support

  • Supply and return duct runs match approved layout
  • Duct sizing appears consistent with design and branch takeoffs
    Check main trunks, branch ducts, and transitions for obvious undersizing, crushing, or unapproved reductions.
  • Ducts are properly supported and hung at appropriate intervals
    Look for secure straps, hangers, and support at joints, offsets, and long horizontal runs.
  • Duct joints, seams, and connections are sealed and mechanically fastened
  • Flexible duct runs are not kinked, crushed, or excessively stretched

Registers, Returns, and Vent Terminations

  • Supply register locations match plans and room layout
  • Return air openings are correctly located and unobstructed
  • Bath, kitchen, dryer, or other exhaust vent terminations are routed to approved exterior locations
    Verify terminations are not blocked, damaged, or terminating in prohibited locations.
  • Registers, grilles, and boots are securely installed and aligned

Combustion Air, Venting, and Safety Provisions

  • Combustion air openings or ducts provided where required
  • Flue venting is routed, supported, and connected per approved design
  • Vent penetrations are properly sealed and clear of combustible interference
    Verify clearances to framing, insulation, and other materials per manufacturer instructions and applicable code.
  • Condensate drain slope and trap arrangement are installed correctly

Pre-Drywall Readiness and Sign-Off

  • No open deficiencies that would be concealed by drywall
  • Required photos captured for rough-in verification
  • Inspector or competent person signature completed
Ask AI Template Studio

Let's customize Residential HVAC Rough-In Walk-Through Inspection.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?