Quality Lab Instrument Calibration Log
Quality Lab Instrument Calibration Log
Inspection template for recording calibration dates, reference standards, results, and out-of-tolerance findings for laboratory test instruments to confirm equipment remains within calibration and supports valid test results.
Inspection Details
-
Instrument ID and asset tag recorded
Enter the unique instrument identifier, asset tag, or serial number for the device being calibrated.
-
Instrument name and model recorded
Document the instrument name, manufacturer, and model number.
-
Calibration date and time recorded
Record the date and time the calibration was performed.
-
Inspector or technician name recorded
Record the person performing or verifying the calibration.
Calibration Standard and Traceability
-
Reference standard identified
Record the calibration standard, reference device, or certified artifact used.
-
Reference standard certification current
Confirm the reference standard certification or traceability documentation is current and valid.
-
Traceability to recognized standard documented
Confirm traceability is documented to an accepted calibration hierarchy or accredited source, as applicable to the lab's quality system.
-
Calibration procedure or SOP referenced
Record the procedure, work instruction, or SOP used for the calibration.
-
Environmental conditions within required range
Confirm temperature, humidity, vibration, or other required conditions were within the calibration procedure limits during the check.
Calibration Results
-
As-found condition recorded
Document the instrument condition before adjustment, including any drift or out-of-tolerance observations.
-
As-left condition recorded
Document the final calibrated condition after adjustment or correction.
-
Measured calibration result within tolerance
Confirm the measured result is within the acceptable tolerance specified by the procedure or manufacturer.
-
Calibration points verified
Enter the number of calibration points checked during the verification.
-
Measurement uncertainty documented
Confirm measurement uncertainty was recorded when required by the calibration method or quality system.
Equipment Status and Non-Conformance
-
Instrument labeled with current calibration status
Confirm the instrument displays a current calibration label or equivalent status marking.
-
Calibration due date recorded
Record the next calibration due date or expiration date.
-
Out-of-tolerance condition identified
Indicate whether any out-of-tolerance or failed calibration condition was found.
-
Affected test results assessed for impact
Confirm any potentially affected test results were reviewed for validity and dispositioned per procedure when the instrument was out of tolerance.
Corrective Actions and Approval
-
Corrective action documented for any failure
Describe repairs, adjustments, retesting, quarantine, or other corrective actions taken for failed or out-of-tolerance items.
-
Supervisor or quality reviewer approval
Signature of the reviewer approving the calibration record and any required follow-up.
-
Calibration record complete and legible
Confirm the record is complete, legible, and suitable for audit review.