Grocery Bakery Proofer Temperature and Humidity Log
Grocery Bakery Proofer Temperature and Humidity Log
Daily log for monitoring grocery bakery proofer temperature and humidity conditions, with corrective action documentation for out-of-specification readings. Supports food safety compliance and product quality consistency.
Inspection Details
-
Inspection Date
Date on which proofer readings are being recorded.
-
Proofer Unit ID / Location
Identify the specific proofer unit being logged (e.g., 'Proofer #1 – Bread Line', 'Proofer #2 – Rolls').
-
Inspector Name
Full name of the bakery associate or supervisor completing this log.
-
Shift
Select the shift during which this log is being completed.
AM Proofer Check
-
AM Check Time
Record the exact time the AM reading was taken.
-
AM Proofer Temperature (°F)
Measure and record the proofer cabinet temperature. Acceptable range: 80–95°F. A reading outside this range is out-of-specification and requires corrective action.
-
AM Relative Humidity (%RH)
Measure and record the proofer relative humidity. Acceptable range: 75–85% RH. Readings outside this range may result in improper dough proofing and product defects.
-
AM Readings Within Acceptable Range?
Confirm both temperature and humidity readings fall within acceptable specification. Select 'No' if either reading is out-of-spec.
Midday Proofer Check
-
Midday Check Time
Record the exact time the midday reading was taken.
-
Midday Proofer Temperature (°F)
Measure and record the proofer cabinet temperature. Acceptable range: 80–95°F.
-
Midday Relative Humidity (%RH)
Measure and record the proofer relative humidity. Acceptable range: 75–85% RH.
-
Midday Readings Within Acceptable Range?
Confirm both temperature and humidity readings fall within acceptable specification.
PM / Closing Proofer Check
-
PM Check Time
Record the exact time the PM/closing reading was taken.
-
PM Proofer Temperature (°F)
Measure and record the proofer cabinet temperature. Acceptable range: 80–95°F.
-
PM Relative Humidity (%RH)
Measure and record the proofer relative humidity. Acceptable range: 75–85% RH.
-
PM Readings Within Acceptable Range?
Confirm both temperature and humidity readings fall within acceptable specification.
Equipment Condition Check
-
Proofer door seals are intact and free of visible gaps or damage
Inspect door gaskets for tears, compression failure, or gaps that could cause temperature or humidity loss.
-
Thermometer / hygrometer calibration is current (calibrated within last 90 days)
Verify that the temperature and humidity monitoring instruments have a current calibration sticker or log entry. Per FDA Food Code 2022 §4-203.11, temperature-measuring devices must be accurate to ±2°F.
-
Proofer interior is clean and free of mold, residue, or standing water
Visually inspect the proofer interior surfaces, trays, and drain for cleanliness. Mold or standing water indicates a sanitation deficiency.
-
Steam/humidity generator is functioning and water reservoir is filled
Confirm the humidity source is operational and water level is adequate for the next production period.
Corrective Action Documentation
-
Was any out-of-specification reading recorded today?
Select 'Yes' if any temperature or humidity reading fell outside the acceptable range during any check period.
-
Out-of-Spec Reading(s) — Check Period and Value
Identify which check period(s) had out-of-spec readings and record the actual values observed (e.g., 'AM – Temp: 100°F; Midday – Humidity: 65% RH').
-
Corrective Action Taken
Describe the corrective action(s) taken to restore proofer conditions to within specification (e.g., adjusted thermostat, refilled water reservoir, called maintenance, discarded affected dough batch).
-
Time Conditions Returned to Specification
Record the time at which proofer temperature and humidity returned to the acceptable range following corrective action.
-
Was affected dough product evaluated for safety and quality before use?
If dough was held in an out-of-spec proofer, confirm it was evaluated by the Person-In-Charge (PIC) per FDA Food Code 2022 §2-101 before being baked or discarded.
-
Supervisor Notified of Out-of-Spec Condition?
Confirm that the bakery supervisor or Person-In-Charge was notified of any out-of-specification condition recorded today.
Ask AI