Geothermal Loop Purge and Antifreeze Commissioning Inspection

Geothermal Loop Purge and Antifreeze Commissioning Inspection

Commissioning inspection record for closed-loop ground source heat exchanger systems, documenting purge performance, debris removal, antifreeze concentration, pressure test results, and final loop readiness before connection to the building system.

Inspection Details

  • Project / site name
  • Loop system identifier
    Identify the ground loop, header, or manifold being inspected.
  • Inspection date and time
  • Inspector name and company
  • Commissioning phase

Circuit Purge and Flushing Verification

  • All circuits purged individually or in verified groups
  • Minimum flushing velocity achieved for each circuit
    Record the measured flushing velocity for the slowest circuit and confirm it meets the project specification or manufacturer requirement.
  • Number of circuits verified
  • Air removed from loop
  • Debris collected during purge
    Describe visible debris, sediment, pipe shavings, or other contaminants removed from the loop.
  • Strainer or filter cleaned during purge

Antifreeze Mix Verification

  • Antifreeze type
  • Measured antifreeze concentration
    Enter the measured concentration by refractometer, hydrometer, or approved test method.
  • Freeze protection verified against design minimum temperature
  • Antifreeze solution mixed uniformly
  • Test method used for concentration

Pressure, Flow, and Leak Check

  • Loop pressure at completion
    Record the final stabilized loop pressure after purge and fill.
  • Pressure test held for required duration
  • No visible leaks at piping, fittings, valves, or headers
  • Pressure drop observed during hold
    If applicable, record the measured pressure loss during the hold period.

Final Readiness and Sign-Off

  • Loop flushed, filled, and ready for connection
  • Outstanding deficiencies or non-conformances
    List any unresolved items, corrective actions, or follow-up requirements.
  • Corrective action assigned
  • Inspector signature
Ask AI Template Studio

Let's customize Geothermal Loop Purge and Antifreeze Commissioning Inspection.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?