Radiology Equipment Daily QC

Radiology Equipment Daily QC

Daily quality control on radiography / fluoroscopy / CT equipment per ACR + state radiation safety. Includes warm-up, image quality, and lead-apron inspection.

Inspection Details

  • Equipment type inspected
    Select the primary modality being inspected.
  • Room / suite identifier
    Enter the room number, suite name, or asset identifier.
  • Inspection date and time
    Record when the daily QC inspection was completed.

Equipment Warm-Up and Operational Readiness

  • System powered on without error messages
    Verify the console, generator, and imaging system initialize normally with no active fault codes or startup alarms.
  • Required warm-up sequence completed
    Confirm the manufacturer-required warm-up procedure was completed before patient use.
  • Tube, detector, and gantry movement normal
    Verify smooth movement and normal mechanical operation of the tube, detector, gantry, table, and any motorized components applicable to the modality.
  • Collimation and positioning lights functional
    Verify collimator control and positioning lights are visible and respond correctly.
  • Emergency stop / abort controls functional
    Verify emergency stop, exposure abort, or scan abort controls are accessible and functional as applicable to the modality.
  • Daily QC log reviewed for unresolved prior deficiencies
    Confirm prior-day deficiencies, non-conformances, or service tickets have been reviewed and addressed before use.

Image Quality and Performance Checks

  • Reference image or phantom image meets acceptance criteria
    Verify the daily reference image, phantom image, or test exposure demonstrates expected contrast, uniformity, and artifact-free appearance per site criteria.
  • No visible artifacts on image display
    Confirm there are no streaks, banding, dead pixels, shading defects, or other image artifacts affecting diagnostic quality.
  • Exposure indicators within expected range
    Verify exposure index, dose indicator, or CTDI-related daily check values are within the facility's acceptable range.
  • Fluoroscopy image chain and last-image hold functional
    For fluoroscopy systems, verify live image display, last-image hold, and image retention functions operate normally.
  • CT scout / localizer image acceptable
    For CT systems, verify scout or localizer image quality is acceptable and free of obvious artifacts or positioning errors.
  • Image quality comments
    Document any observed image quality deficiency, non-conformance, or corrective action taken.

Radiation Safety and Protective Equipment

  • Lead aprons inspected for visible damage
    Inspect lead aprons for cracks, tears, delamination, broken straps, or other visible defects before use.
  • Lead apron and thyroid shield inventory checked
    Confirm all required protective garments are present, labeled, and available for staff use.
  • Protective apparel storage prevents folding or damage
    Verify aprons and shields are stored on proper hangers or racks to prevent creasing and material degradation.
  • Radiation warning signs and controlled access posted
    Confirm required radiation warning signage, room postings, and access controls are in place and visible.
  • Dosimetry badges present where required
    Verify personnel dosimeters are worn or available according to department radiation safety procedures.
  • Any radiation safety deficiency identified
    Indicate whether a radiation safety deficiency, non-conformance, or reportable condition was identified during this inspection.

Documentation and Escalation

  • Deficiencies documented and escalated
    Confirm any failed item was documented, communicated to the appropriate supervisor, and escalated to service or radiation safety as needed.
  • Equipment removed from service if required
    If a critical item failed, confirm the equipment was taken out of service and tagged according to site lockout-tagout or equipment control procedures.
  • Inspector comments
    Record additional observations, corrective actions, or follow-up requirements.
  • Inspector signature
    Signature of the technologist, physicist, or authorized inspector completing the daily QC.
Ask AI Template Studio

Let's customize Radiology Equipment Daily QC.

Tell me how you'd like to adapt it. For example:

  • Add a question about delivery time.
  • Make it shorter — 5 questions max.
  • Tailor it for the hospitality industry.
  • Translate the labels into Spanish.
Ask AI Product Advisor

Hi! I'm the MangoApps Product Advisor. I can help you with:

  • Understanding our 40+ workplace apps
  • Finding the right solution for your needs
  • Answering questions about pricing and features
  • Pointing you to free tools you can try right now

What would you like to know?