Heat-Soak Test Cycle Log for Tempered Glass
Heat-Soak Test Cycle Log for Tempered Glass
Inspection log for recording heat-soak oven cycles, batch traceability, and post-cycle outcomes for fully tempered glass to help reduce spontaneous breakage associated with nickel sulfide inclusions.
Inspection Details
- Inspection date and time
- Inspector name and role
- Facility, line, or oven ID
- Reference SOP or work instruction
- Batch or lot number
Glass Batch Identification and Load Details
- Glass product description
- Glass thickness
- Number of panes or lites loaded
-
Batch identification method verified
Confirm each load is traceable to a specific batch, lot, or production run.
- Load map or rack position recorded
Oven Cycle Parameters
- Preheat temperature setpoint
- Actual oven temperature at start
- Target dwell time
- Actual dwell time completed
- Temperature uniformity within oven load zone
Cycle Monitoring and Safety Controls
- Oven door interlocks and safety guards functional
- Overtemperature alarm tested and operational
- Recorded cycle start and end timestamps match log
- PPE used during loading and unloading
Post-Cycle Outcomes and Deficiencies
-
Breakage observed during or after cycle
Record whether any panes fractured during the heat-soak cycle or during unloading/cooldown.
- Number of panes broken
-
Visible defects or non-conformances noted
Document any warping, edge damage, label mismatch, contamination, or other non-conformance.
- Disposition of tested batch
Corrective Actions and Sign-Off
-
Corrective action required
Indicate whether any deviation, failure, or non-conformance requires follow-up action.
- Corrective action details
- Supervisor or quality approval