Grocery Deli Case Temperature Log
Grocery Deli Case Temperature Log
Scheduled temperature recording inspection for grocery deli display cases, covering hot and cold hold zones to ensure compliance with FDA Food Code 2022 and OSHA standards. Tracks readings across multiple check periods per day.
Inspection Setup
-
Inspection Date
Date on which this temperature log is being completed.
-
Inspector Name
Full name of the employee completing this log.
-
Deli Case / Unit Identifier
Enter the case number, label, or location (e.g., 'Cold Case 1 – Front', 'Hot Case A – Rotisserie').
-
Thermometer ID / Calibration Status
Record the thermometer used and confirm it has been calibrated within the required interval (FDA Food Code 2022 §4-502.11).
-
Check Period
Select the scheduled check period for this log entry.
Cold Hold Zone Temperature
-
Cold Case Air Temperature (°F)
Record the ambient air temperature displayed by the case thermometer or measured with a calibrated probe at the warmest point of the case.
-
Cold Product Internal Temperature – Sample 1 (°F)
Insert calibrated probe into the thickest part of a representative cold deli product (e.g., sliced turkey, cheese). Record reading.
-
Cold Product Internal Temperature – Sample 2 (°F)
Record a second product temperature from a different item or location within the same cold case to verify uniformity.
-
Cold Case Temperature Within Acceptable Range (≤41°F)
Confirm all cold hold readings are at or below 41°F. If any reading exceeds 41°F, corrective action must be initiated immediately.
Hot Hold Zone Temperature
-
Hot Case Air Temperature (°F)
Record the ambient air temperature of the hot hold case as shown on the unit thermometer or measured with a calibrated probe.
-
Hot Product Internal Temperature – Sample 1 (°F)
Insert calibrated probe into the thickest part of a representative hot deli product (e.g., rotisserie chicken, hot wings). Record reading.
-
Hot Product Internal Temperature – Sample 2 (°F)
Record a second product temperature from a different hot item or location within the same hot case to verify uniformity.
-
Hot Case Temperature Within Acceptable Range (≥135°F)
Confirm all hot hold readings are at or above 135°F. If any reading falls below 135°F, corrective action must be initiated immediately.
Case Equipment Condition
-
Case door seals / gaskets are intact, clean, and free of tears or gaps
Damaged gaskets allow warm air infiltration in cold cases and heat loss in hot cases, compromising hold temperatures.
-
Case interior is free of excessive ice buildup (cold cases) or grease accumulation (hot cases)
Ice buildup on evaporator coils reduces cooling efficiency; grease accumulation in hot cases is a fire hazard (NFPA 1) and a sanitation deficiency.
-
Case display lighting and fans are operational
Non-functional fans reduce air circulation and temperature uniformity. Report any deficiency to maintenance immediately.
-
Case unit thermometer is visible, legible, and in place
A missing or unreadable unit thermometer is a regulatory deficiency under FDA Food Code 2022 §4-203.11.
Corrective Actions and Sign-Off
-
Were any temperature out-of-range readings identified during this check?
Select 'Yes' if any cold hold reading exceeded 41°F or any hot hold reading fell below 135°F.
-
Corrective Action Taken (if applicable)
Describe corrective actions taken: product discarded, case adjusted, maintenance notified, product relocated, manager notified, etc. Enter 'N/A' if no out-of-range readings were found.
-
Time Corrective Action Completed
Record the time corrective action was completed, or 'N/A' if no action was required.
-
All temperatures are within acceptable ranges OR corrective actions have been documented and completed
Inspector confirms that either all readings are compliant, or all deficiencies have been addressed and documented per FDA Food Code 2022 §8-405.11.
-
Inspector Signature
Inspector signature confirming accuracy of all recorded temperatures and corrective actions.
Ask AI
Template Studio