Brick Freeze-Thaw Durability Test Log (ASTM C67)
Brick Freeze-Thaw Durability Test Log (ASTM C67)
Inspection log for recording freeze-thaw cycling results on sampled brick in accordance with ASTM C67 to support qualification of Grade SW severe weathering brick and document durability evidence.
Inspection Identification and Traceability
-
Project, batch, and test lot identification recorded
Record the project name, brick batch or lot number, and test lot identifier.
-
Sample source and manufacturer documented
Identify the manufacturer, plant, product line, and sampling location or source.
-
ASTM C67 freeze-thaw test reference confirmed
Confirm the test is being performed and recorded under ASTM C67 procedures.
-
Target classification for Grade SW severe weathering documented
Confirm the test objective is to support Grade SW severe weathering qualification or equivalent durability evidence.
Specimen Condition and Preparation
-
Number of specimens tested
Enter the total number of brick specimens included in the test set.
-
Specimens visually inspected before cycling
Confirm each specimen was inspected for pre-existing cracks, chips, spalls, or other defects before testing.
-
Specimen dimensions recorded
Record measured dimensions or reference dimensions for the specimens used in the test.
-
Pre-test specimen condition documented with photos
Attach photographs showing specimen condition before freeze-thaw cycling.
-
Conditioning method and saturation state documented
Describe the conditioning method used before cycling, including moisture state or saturation procedure.
Freeze-Thaw Cycling Parameters
-
Test chamber temperature range within specified limits
Record the chamber temperature range observed during cycling.
-
Freeze-thaw cycle count completed
Enter the number of cycles completed for the test set.
-
Cycle duration and dwell times recorded
Document freeze and thaw dwell times, ramp times, and any hold periods used in the test sequence.
-
Water exposure or immersion conditions documented
Record whether specimens were immersed, sprayed, or otherwise exposed to water during cycling and describe the method.
-
Calibration status of chamber and measurement devices verified
Confirm temperature sensors, timers, and any balance or measurement devices were within calibration at time of test.
Post-Test Results and Defects
-
Visible cracking, spalling, or disintegration observed
Indicate whether any visible cracking, spalling, scaling, or disintegration was observed after cycling.
-
Mass change recorded
Record the mass change for the specimen set before and after testing.
-
Individual specimen damage summary documented
Summarize the condition of each specimen or identify any outliers, failures, or notable damage patterns.
-
Post-test photographs captured
Attach photographs showing the final condition of the specimens after freeze-thaw cycling.
-
Test anomalies or interruptions recorded
Document any chamber malfunction, power interruption, specimen handling issue, or other anomaly affecting results.
Compliance Review, Disposition, and Sign-Off
-
Results meet project acceptance criteria for severe weathering brick
Confirm whether the observed results meet the specified acceptance criteria for Grade SW or project-defined durability requirements.
-
Non-conformance or corrective action documented if failed
If the test did not meet criteria, document the non-conformance, disposition, and any corrective action required.
-
Reference report number or laboratory record entered
Enter the linked report number, lab record ID, or chain-of-custody reference for traceability.
-
Inspector or laboratory sign-off completed
Capture the signature of the responsible inspector, technician, or laboratory representative.